Hakai > Data > Sensor Network > TSN2.1hourSamples (2024-02-02 00:00:00 PST - 2024-04-26 13:00:00 PST) Hakai, a Tula Foundation program
ParameterValue
Start time2024-02-02 00:00:00 PST
End time2024-04-26 13:00:00 PST
Generated time2024-04-26 13:24:06 PST
Sample interval1 hour
Measurements183
Terrestrial sensor node #2
Disclaimer: 0

NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph

Measurement summary

Station nameMeasurement nameMeasurement unitLogger functionMeasurements foundMeasurements missingSensor information/measurement calculation
SSN708Rain24HrSSN708 (24hourRain)mm24 hour total02030TB4: Tipping-bucket Rain Gauge SN=13-515
=total(total(SSN708.5minuteSamples.Rain,12),24)
TSN2TAirTSN2_Med (AirTemp_Med)deg CMed20300HC2S3: Temperature and Relative Humidity Probe SN=61081140
=median(TSN2.5minuteSamples.AirTemp_Avg)
TSN2TAirTSN2_Avg (AirTemp_Avg)deg CAvg20300HC2S3: Temperature and Relative Humidity Probe SN=61081140
=avg(TSN2.5minuteSamples.AirTemp_Avg)
TSN2TAirTSN2_Min (AirTemp_Min)deg CMin20300HC2S3: Temperature and Relative Humidity Probe SN=61081140
=min(TSN2.5minuteSamples.AirTemp_Avg)
TSN2TAirTSN2_Max (AirTemp_Max)deg CMax20300HC2S3: Temperature and Relative Humidity Probe SN=61081140
=max(TSN2.5minuteSamples.AirTemp_Avg)
TSN2RHTSN2_Med (RH_Med)%Med20300HC2S3: Temperature and Relative Humidity Probe SN=61081140
=median(TSN2.5minuteSamples.RH_Avg)
TSN2RHTSN2_Avg (RH_Avg)%Avg20300HC2S3: Temperature and Relative Humidity Probe SN=61081140
=avg(TSN2.5minuteSamples.RH_Avg)
TSN2RHTSN2_Min (RH_Min)%Min20300HC2S3: Temperature and Relative Humidity Probe SN=61081140
=min(TSN2.5minuteSamples.RH_Avg)
TSN2RHTSN2_Max (RH_Max)%Max20300HC2S3: Temperature and Relative Humidity Probe SN=61081140
=max(TSN2.5minuteSamples.RH_Avg)
TSN2WTW7 Soil TempP_Med (T109_C_Med)deg CMed02030109: Temperature Probe
=median(TSN2.5minuteSamples.T109_C_Avg)
TSN2WTW7 Soil TempP_Avg (T109_C_Avg)deg CAvg02030109: Temperature Probe
=avg(TSN2.5minuteSamples.T109_C_Avg)
TSN2WTW7 Soil TempP_Min (T109_C_Min)deg CMin02030109: Temperature Probe
=min(TSN2.5minuteSamples.T109_C_Avg)
TSN2WTW7 Soil TempP_Max (T109_C_Max)deg CMax02030109: Temperature Probe
=max(TSN2.5minuteSamples.T109_C_Avg)
TSN2WTW7 VWC_Avg (WC_VWC_Avg)m3/m3Avg02030CS650: Soil Water Content Reflectometer SN=7493
TSN2WTW7 VWC_Min (WC_VWC_Min)m3/m3Min02030CS650: Soil Water Content Reflectometer SN=7493
TSN2WTW7 VWC_Max (WC_VWC_Max)m3/m3Max02030CS650: Soil Water Content Reflectometer SN=7493
TSN2WTW7 VWC_Std (WC_VWC_Std)m3/m3Std02030CS650: Soil Water Content Reflectometer SN=7493
TSN2WTW8 VWC_Avg (WC_VWC_2_Avg)m3/m3Avg02030CS655: Soil Water Content Reflectometer SN=7499
TSN2WTW8 VWC_Min (WC_VWC_2_Min)m3/m3Min02030CS655: Soil Water Content Reflectometer SN=7499
TSN2WTW8 VWC_Max (WC_VWC_2_Max)m3/m3Max02030CS655: Soil Water Content Reflectometer SN=7499
TSN2WTW8 VWC_Std (WC_VWC_2_Std)m3/m3Std02030CS655: Soil Water Content Reflectometer SN=7499
TSN2WTW7 Soil TempTDR_Avg (WC_T_Avg)deg CAvg02030CS650: Soil Water Content Reflectometer SN=7493
TSN2WTW7 Soil TempTDR_Min (WC_T_Min)deg CMin02030CS650: Soil Water Content Reflectometer SN=7493
TSN2WTW7 Soil TempTDR_Max (WC_T_Max)deg CMax02030CS650: Soil Water Content Reflectometer SN=7493
TSN2WTW7 Soil TempTDR_Std (WC_T_Std)deg CStd02030CS650: Soil Water Content Reflectometer SN=7493
TSN2WTW8 Soil TempTDR_Avg (WC_T_2_Avg)deg CAvg02030CS655: Soil Water Content Reflectometer SN=7499
TSN2WTW8 Soil TempTDR_Min (WC_T_2_Min)deg CMin02030CS655: Soil Water Content Reflectometer SN=7499
TSN2WTW8 Soil TempTDR_Max (WC_T_2_Max)deg CMax02030CS655: Soil Water Content Reflectometer SN=7499
TSN2WTW8 Soil TempTDR_Std (WC_T_2_Std)deg CStd02030CS655: Soil Water Content Reflectometer SN=7499
TSN2TWtr_WTW7_Med (Well_PT_1_Temp_Med)deg CMed02030KPSI 353: Pressure Transducer SN=1504419
=median(fillGaps(TSN2.5minuteSamples.Well_PT_1_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW7_Avg (Well_PT_1_Temp_Avg)deg CAvg02030KPSI 353: Pressure Transducer SN=1504419
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_1_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW7_Min (Well_PT_1_Temp_Min)deg CMin02030KPSI 353: Pressure Transducer SN=1504419
=min(fillGaps(TSN2.5minuteSamples.Well_PT_1_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW7_Max (Well_PT_1_Temp_Max)deg CMax02030KPSI 353: Pressure Transducer SN=1504419
=max(fillGaps(TSN2.5minuteSamples.Well_PT_1_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW8_Med (Well_PT_2_Temp_Med)deg CMed02030KPSI 353: Pressure Transducer SN=1504415
=median(fillGaps(TSN2.5minuteSamples.Well_PT_2_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW8_Avg (Well_PT_2_Temp_Avg)deg CAvg02030KPSI 353: Pressure Transducer SN=1504415
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_2_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW8_Min (Well_PT_2_Temp_Min)deg CMin02030KPSI 353: Pressure Transducer SN=1504415
=min(fillGaps(TSN2.5minuteSamples.Well_PT_2_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW8_Max (Well_PT_2_Temp_Max)deg CMax02030KPSI 353: Pressure Transducer SN=1504415
=max(fillGaps(TSN2.5minuteSamples.Well_PT_2_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW9_Med (Well_PT_3_Temp_Med)deg CMed02030KPSI 353: Pressure Transducer SN=1504416
=median(fillGaps(TSN2.5minuteSamples.Well_PT_3_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW9_Avg (Well_PT_3_Temp_Avg)deg CAvg02030KPSI 353: Pressure Transducer SN=1504416
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_3_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW9_Min (Well_PT_3_Temp_Min)deg CMin02030KPSI 353: Pressure Transducer SN=1504416
=min(fillGaps(TSN2.5minuteSamples.Well_PT_3_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW9_Max (Well_PT_3_Temp_Max)deg CMax02030KPSI 353: Pressure Transducer SN=1504416
=max(fillGaps(TSN2.5minuteSamples.Well_PT_3_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW16_Med (Well_PT_4_Temp_Med)deg CMed20300KPSI 353: Pressure Transducer SN=1505967
=median(fillGaps(TSN2.5minuteSamples.Well_PT_4_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW16_Avg (Well_PT_4_Temp_Avg)deg CAvg20300KPSI 353: Pressure Transducer SN=1505967
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_4_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW16_Min (Well_PT_4_Temp_Min)deg CMin20300KPSI 353: Pressure Transducer SN=1505967
=min(fillGaps(TSN2.5minuteSamples.Well_PT_4_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW16_Max (Well_PT_4_Temp_Max)deg CMax20300KPSI 353: Pressure Transducer SN=1505967
=max(fillGaps(TSN2.5minuteSamples.Well_PT_4_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW17_Med (Well_PT_5_Temp_Med)deg CMed20300KPSI 353: Pressure Transducer SN=1505964
=median(fillGaps(TSN2.5minuteSamples.Well_PT_5_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW17_Avg (Well_PT_5_Temp_Avg)deg CAvg20300KPSI 353: Pressure Transducer SN=1505964
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_5_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW17_Min (Well_PT_5_Temp_Min)deg CMin20300KPSI 353: Pressure Transducer SN=1505964
=min(fillGaps(TSN2.5minuteSamples.Well_PT_5_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW17_Max (Well_PT_5_Temp_Max)deg CMax20300KPSI 353: Pressure Transducer SN=1505964
=max(fillGaps(TSN2.5minuteSamples.Well_PT_5_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW18_Med (Well_PT_6_Temp_Med)deg CMed20300KPSI 353: Pressure Transducer SN=1505963
=median(fillGaps(TSN2.5minuteSamples.Well_PT_6_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW18_Avg (Well_PT_6_Temp_Avg)deg CAvg20300KPSI 353: Pressure Transducer SN=1505963
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_6_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW18_Min (Well_PT_6_Temp_Min)deg CMin20300KPSI 353: Pressure Transducer SN=1505963
=min(fillGaps(TSN2.5minuteSamples.Well_PT_6_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW18_Max (Well_PT_6_Temp_Max)deg CMax20300KPSI 353: Pressure Transducer SN=1505963
=max(fillGaps(TSN2.5minuteSamples.Well_PT_6_Temp_Avg,maxGapsFilled=240))
TSN2WTD_WTW7 (WTW7_wtd)cmcalculated02030Levelogger Edge 3001: Water Level Datalogger SN=2025435/12013305
=fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=33.3),maxGapsFilled=240)
TSN2WTD_WTW7_Med (WTW7_wtd_Med)cmMed02030Levelogger Edge 3001: Water Level Datalogger SN=2025435/12013305
=median(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=33.3),maxGapsFilled=240))
TSN2WTD_WTW7_Avg (WTW7_wtd_Avg)cmAvg02030Levelogger Edge 3001: Water Level Datalogger SN=2025435/12013305
=avg(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=33.3),maxGapsFilled=240))
TSN2WTD_WTW7_Min (WTW7_wtd_Min)cmMin02030Levelogger Edge 3001: Water Level Datalogger SN=2025435/12013305
=min(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=33.3),maxGapsFilled=240))
TSN2WTD_WTW7_Max (WTW7_wtd_Max)cmMax02030Levelogger Edge 3001: Water Level Datalogger SN=2025435/12013305
=max(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=33.3),maxGapsFilled=240))
TSN2WTD_WTW8 (WTW8_wtd)cmcalculated02030Levelogger Edge 3001: Water Level Datalogger SN=2025417
=fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=96.5,riserHeight=40.5),maxGapsFilled=240)
TSN2WTD_WTW8_Med (WTW8_wtd_Med)cmMed02030Levelogger Edge 3001: Water Level Datalogger SN=2025417
=median(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=96.5,riserHeight=40.5),maxGapsFilled=240))
TSN2WTD_WTW8_Avg (WTW8_wtd_Avg)cmAvg02030Levelogger Edge 3001: Water Level Datalogger SN=2025417
=avg(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=96.5,riserHeight=40.5),maxGapsFilled=240))
TSN2WTD_WTW8_Min (WTW8_wtd_Min)cmMin02030Levelogger Edge 3001: Water Level Datalogger SN=2025417
=min(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=96.5,riserHeight=40.5),maxGapsFilled=240))
TSN2WTD_WTW8_Max (WTW8_wtd_Max)cmMax02030Levelogger Edge 3001: Water Level Datalogger SN=2025417
=max(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=96.5,riserHeight=40.5),maxGapsFilled=240))
TSN2WTD_WTW9 (WTW9_wtd)cmcalculated02030Levelogger Edge 3001: Water Level Datalogger SN=2025446/2012905
=fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=34.5),maxGapsFilled=240)
TSN2WTD_WTW9_Med (WTW9_wtd_Med)cmMed02030Levelogger Edge 3001: Water Level Datalogger SN=2025446/2012905
=median(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=34.5),maxGapsFilled=240))
TSN2WTD_WTW9_Avg (WTW9_wtd_Avg)cmAvg02030Levelogger Edge 3001: Water Level Datalogger SN=2025446/2012905
=avg(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=34.5),maxGapsFilled=240))
TSN2WTD_WTW9_Min (WTW9_wtd_Min)cmMin02030Levelogger Edge 3001: Water Level Datalogger SN=2025446/2012905
=min(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=34.5),maxGapsFilled=240))
TSN2WTD_WTW9_Max (WTW9_wtd_Max)cmMax02030Levelogger Edge 3001: Water Level Datalogger SN=2025446/2012905
=max(fillGaps(waterTableDepth(rangeClip(minimumValue=5.0)&scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140.0,riserHeight=34.5),maxGapsFilled=240))
TSN2WTD_WTW16 (WTW16_wtd)cmcalculated20300KPSI 353: Pressure Transducer SN=1505967
=fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240)
TSN2WTD_WTW16_Med (WTW16_wtd_Med)cmMed20300KPSI 353: Pressure Transducer SN=1505967
=median(fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240))
TSN2WTD_WTW16_Avg (WTW16_wtd_Avg)cmAvg20300KPSI 353: Pressure Transducer SN=1505967
=avg(fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240))
TSN2WTD_WTW16_Min (WTW16_wtd_Min)cmMin20300KPSI 353: Pressure Transducer SN=1505967
=min(fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240))
TSN2WTD_WTW16_Max (WTW16_wtd_Max)cmMax20300KPSI 353: Pressure Transducer SN=1505967
=max(fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240))
TSN2WTD_WTW17 (WTW17_wtd)cmcalculated20300KPSI 353: Pressure Transducer SN=1505964
=waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40)
TSN2WTD_WTW17_Med (WTW17_wtd_Med)cmMed20300KPSI 353: Pressure Transducer SN=1505964
=median(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40))
TSN2WTD_WTW17_Avg (WTW17_wtd_Avg)cmAvg20300KPSI 353: Pressure Transducer SN=1505964
=avg(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40))
TSN2WTD_WTW17_Min (WTW17_wtd_Min)cmMin20300KPSI 353: Pressure Transducer SN=1505964
=min(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40))
TSN2WTD_WTW17_Max (WTW17_wtd_Max)cmMax20300KPSI 353: Pressure Transducer SN=1505964
=max(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40))
TSN2WTD_WTW18 (WTW18_wtd)cmcalculated20300KPSI 353: Pressure Transducer SN=1505963
=waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40)
TSN2WTD_WTW18_Med (WTW18_wtd_Med)cmMed20300KPSI 353: Pressure Transducer SN=1505963
=median(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40))
TSN2WTD_WTW18_Avg (WTW18_wtd_Avg)cmAvg20300KPSI 353: Pressure Transducer SN=1505963
=avg(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40))
TSN2WTD_WTW18_Min (WTW18_wtd_Min)cmMin20300KPSI 353: Pressure Transducer SN=1505963
=min(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40))
TSN2WTD_WTW18_Max (WTW18_wtd_Max)cmMax20300KPSI 353: Pressure Transducer SN=1505963
=max(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40))
TSN2TSoilTSN2S4_40_Med (Soil_Temp_1_Med)deg CMed20300109AM: Soil Temperature Probe SN=c1551
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_40_Avg (Soil_Temp_1_Avg)deg CAvg20300109AM: Soil Temperature Probe SN=c1551
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_40_Min (Soil_Temp_1_Min)deg CMin20300109AM: Soil Temperature Probe SN=c1551
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_40_Max (Soil_Temp_1_Max)deg CMax20300109AM: Soil Temperature Probe SN=c1551
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_10_Med (Soil_Temp_2_Med)deg CMed1483547109AM: Soil Temperature Probe SN=c1553
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_10_Avg (Soil_Temp_2_Avg)deg CAvg1483547109AM: Soil Temperature Probe SN=c1553
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_10_Min (Soil_Temp_2_Min)deg CMin1483547109AM: Soil Temperature Probe SN=c1553
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_10_Max (Soil_Temp_2_Max)deg CMax1483547109AM: Soil Temperature Probe SN=c1553
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_25_Med (Soil_Temp_3_Med)deg CMed20300109AM: Soil Temperature Probe SN=c1555
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_25_Avg (Soil_Temp_3_Avg)deg CAvg20300109AM: Soil Temperature Probe SN=c1555
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_25_Min (Soil_Temp_3_Min)deg CMin20300109AM: Soil Temperature Probe SN=c1555
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_25_Max (Soil_Temp_3_Max)deg CMax20300109AM: Soil Temperature Probe SN=c1555
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_25_Med (Soil_Temp_4_Med)deg CMed20300109AM: Soil Temperature Probe SN=c1558
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_25_Avg (Soil_Temp_4_Avg)deg CAvg20300109AM: Soil Temperature Probe SN=c1558
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_25_Min (Soil_Temp_4_Min)deg CMin20300109AM: Soil Temperature Probe SN=c1558
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_25_Max (Soil_Temp_4_Max)deg CMax20300109AM: Soil Temperature Probe SN=c1558
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_10_Med (Soil_Temp_5_Med)deg CMed20300109AM: Soil Temperature Probe SN=c1560
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_10_Avg (Soil_Temp_5_Avg)deg CAvg20300109AM: Soil Temperature Probe SN=c1560
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_10_Min (Soil_Temp_5_Min)deg CMin20300109AM: Soil Temperature Probe SN=c1560
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_10_Max (Soil_Temp_5_Max)deg CMax20300109AM: Soil Temperature Probe SN=c1560
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_40_Med (Soil_Temp_6_Med)deg CMed20300109AM: Soil Temperature Probe SN=c1554
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_40_Avg (Soil_Temp_6_Avg)deg CAvg20300109AM: Soil Temperature Probe SN=c1554
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_40_Min (Soil_Temp_6_Min)deg CMin20300109AM: Soil Temperature Probe SN=c1554
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_40_Max (Soil_Temp_6_Max)deg CMax20300109AM: Soil Temperature Probe SN=c1554
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_10_Med (Soil_Temp_7_Med)deg CMed20300109AM: Soil Temperature Probe SN=c1561
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_10_Avg (Soil_Temp_7_Avg)deg CAvg20300109AM: Soil Temperature Probe SN=c1561
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_10_Min (Soil_Temp_7_Min)deg CMin20300109AM: Soil Temperature Probe SN=c1561
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_10_Max (Soil_Temp_7_Max)deg CMax20300109AM: Soil Temperature Probe SN=c1561
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_25_Med (Soil_Temp_8_Med)deg CMed20300109AM: Soil Temperature Probe SN=c1556
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_25_Avg (Soil_Temp_8_Avg)deg CAvg20300109AM: Soil Temperature Probe SN=c1556
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_25_Min (Soil_Temp_8_Min)deg CMin20300109AM: Soil Temperature Probe SN=c1556
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_25_Max (Soil_Temp_8_Max)deg CMax20300109AM: Soil Temperature Probe SN=c1556
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_40_Med (Soil_Temp_9_Med)deg CMed20300109AM: Soil Temperature Probe SN=c1548
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_40_Avg (Soil_Temp_9_Avg)deg CAvg20300109AM: Soil Temperature Probe SN=c1548
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_40_Min (Soil_Temp_9_Min)deg CMin20300109AM: Soil Temperature Probe SN=c1548
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_40_Max (Soil_Temp_9_Max)deg CMax20300109AM: Soil Temperature Probe SN=c1548
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2ORP_TSN2S4_40_Avg (RP_6_Avg)mVAvg02030Redox Probe SN=RP_6
TSN2ORP_TSN2S4_40_Min (RP_6_Min)mVMin02030Redox Probe SN=RP_6
TSN2ORP_TSN2S4_40_Max (RP_6_Max)mVMax02030Redox Probe SN=RP_6
TSN2ORP_TSN2S4_40_Std (RP_6_Std)mVStd02030Redox Probe SN=RP_6
TSN2ORP_TSN2S5_40_Avg (RP_7_Avg)mVAvg02030Redox Probe SN=RP_7
TSN2ORP_TSN2S5_40_Min (RP_7_Min)mVMin02030Redox Probe SN=RP_7
TSN2ORP_TSN2S5_40_Max (RP_7_Max)mVMax02030Redox Probe SN=RP_7
TSN2ORP_TSN2S5_40_Std (RP_7_Std)mVStd02030Redox Probe SN=RP_7
TSN2ORP_TSN2S6_40_Avg (RP_8_Avg)mVAvg02030Redox Probe SN=RP_8
TSN2ORP_TSN2S6_40_Min (RP_8_Min)mVMin02030Redox Probe SN=RP_8
TSN2ORP_TSN2S6_40_Max (RP_8_Max)mVMax02030Redox Probe SN=RP_8
TSN2ORP_TSN2S6_40_Std (RP_8_Std)mVStd02030Redox Probe SN=RP_8
TSN2ORP_TSN2S7_40_Avg (RP_9_Avg)mVAvg02030Redox Probe SN=RP_9
TSN2ORP_TSN2S7_40_Min (RP_9_Min)mVMin02030Redox Probe SN=RP_9
TSN2ORP_TSN2S7_40_Max (RP_9_Max)mVMax02030Redox Probe SN=RP_9
TSN2ORP_TSN2S7_40_Std (RP_9_Std)mVStd02030Redox Probe SN=RP_9
TSN2ORP_TSN2S8_40_Avg (RP_10_Avg)mVAvg02030Redox Probe SN=RP_10
TSN2ORP_TSN2S8_40_Min (RP_10_Min)mVMin02030Redox Probe SN=RP_10
TSN2ORP_TSN2S8_40_Max (RP_10_Max)mVMax02030Redox Probe SN=RP_10
TSN2ORP_TSN2S8_40_Std (RP_10_Std)mVStd02030Redox Probe SN=RP_10
TSN2ORP_TSN2S4_25_Avg (RP_11_Avg)mVAvg02030Redox Probe SN=RP_11
TSN2ORP_TSN2S4_25_Min (RP_11_Min)mVMin02030Redox Probe SN=RP_11
TSN2ORP_TSN2S4_25_Max (RP_11_Max)mVMax02030Redox Probe SN=RP_11
TSN2ORP_TSN2S4_25_Std (RP_11_Std)mVStd02030Redox Probe SN=RP_11
TSN2ORP_TSN2S5_25_Avg (RP_12_Avg)mVAvg02030Redox Probe SN=RP_12
TSN2ORP_TSN2S5_25_Min (RP_12_Min)mVMin02030Redox Probe SN=RP_12
TSN2ORP_TSN2S5_25_Max (RP_12_Max)mVMax02030Redox Probe SN=RP_12
TSN2ORP_TSN2S5_25_Std (RP_12_Std)mVStd02030Redox Probe SN=RP_12
TSN2ORP_TSN2S6_25_Avg (RP_13_Avg)mVAvg02030Redox Probe SN=RP_13
TSN2ORP_TSN2S6_25_Min (RP_13_Min)mVMin02030Redox Probe SN=RP_13
TSN2ORP_TSN2S6_25_Max (RP_13_Max)mVMax02030Redox Probe SN=RP_13
TSN2ORP_TSN2S6_25_Std (RP_13_Std)mVStd02030Redox Probe SN=RP_13
TSN2ORP_TSN2S7_25_Avg (RP_14_Avg)mVAvg02030Redox Probe SN=RP_14
TSN2ORP_TSN2S7_25_Min (RP_14_Min)mVMin02030Redox Probe SN=RP_14
TSN2ORP_TSN2S7_25_Max (RP_14_Max)mVMax02030Redox Probe SN=RP_14
TSN2ORP_TSN2S7_25_Std (RP_14_Std)mVStd02030Redox Probe SN=RP_14
TSN2ORP_TSN2S8_25_Avg (RP_15_Avg)mVAvg02030Redox Probe SN=RP_15
TSN2ORP_TSN2S8_25_Min (RP_15_Min)mVMin02030Redox Probe SN=RP_15
TSN2ORP_TSN2S8_25_Max (RP_15_Max)mVMax02030Redox Probe SN=RP_15
TSN2ORP_TSN2S8_25_Std (RP_15_Std)mVStd02030Redox Probe SN=RP_15
TSN2ORP_TSN2S4_10_Avg (RP_16_Avg)mVAvg02030Redox Probe SN=RP_16
TSN2ORP_TSN2S4_10_Min (RP_16_Min)mVMin02030Redox Probe SN=RP_16
TSN2ORP_TSN2S4_10_Max (RP_16_Max)mVMax02030Redox Probe SN=RP_16
TSN2ORP_TSN2S4_10_Std (RP_16_Std)mVStd02030Redox Probe SN=RP_16
TSN2ORP_TSN2S5_10_Avg (RP_17_Avg)mVAvg02030Redox Probe SN=RP_17
TSN2ORP_TSN2S5_10_Min (RP_17_Min)mVMin02030Redox Probe SN=RP_17
TSN2ORP_TSN2S5_10_Max (RP_17_Max)mVMax02030Redox Probe SN=RP_17
TSN2ORP_TSN2S5_10_Std (RP_17_Std)mVStd02030Redox Probe SN=RP_17
TSN2ORP_TSN2S6_10_Avg (RP_18_Avg)mVAvg02030Redox Probe SN=RP_18
TSN2ORP_TSN2S6_10_Min (RP_18_Min)mVMin02030Redox Probe SN=RP_18
TSN2ORP_TSN2S6_10_Max (RP_18_Max)mVMax02030Redox Probe SN=RP_18
TSN2ORP_TSN2S6_10_Std (RP_18_Std)mVStd02030Redox Probe SN=RP_18
TSN2ORP_TSN2S7_10_Avg (RP_19_Avg)mVAvg02030Redox Probe SN=RP_19
TSN2ORP_TSN2S7_10_Min (RP_19_Min)mVMin02030Redox Probe SN=RP_19
TSN2ORP_TSN2S7_10_Max (RP_19_Max)mVMax02030Redox Probe SN=RP_19
TSN2ORP_TSN2S7_10_Std (RP_19_Std)mVStd02030Redox Probe SN=RP_19
TSN2ORP_TSN2S8_10_Avg (RP_20_Avg)mVAvg02030Redox Probe SN=RP_20
TSN2ORP_TSN2S8_10_Min (RP_20_Min)mVMin02030Redox Probe SN=RP_20
TSN2ORP_TSN2S8_10_Max (RP_20_Max)mVMax02030Redox Probe SN=RP_20
TSN2ORP_TSN2S8_10_Std (RP_20_Std)mVStd02030Redox Probe SN=RP_20
TSN2BattVolt_AvgVoltsAvg20300CR1000: Data Logger
TSN2BattVolt_MinVoltsMin20300CR1000: Data Logger
TSN2BattVolt_MaxVoltsMax20300CR1000: Data Logger
TSN3Rain24HrTSN3 (24hourRain)mm24 hour total20300TB4: Tipping-bucket Rain Gauge SN=14-1711
=total(total(TSN3.5minuteSamples.Rain,12),24)