Hakai > Data > Sensor Network > Lookout.1hourSamples (2016-11-30 00:00:00 PST - 2017-02-21 23:00:00 PST) Hakai, a Tula Foundation program
ParameterValue
Data (login required)last12weeks-Lookout.1hourSamples.xlsx
Start time2016-11-30 00:00:00 PST
End time2017-02-21 23:00:00 PST
Generated time2017-02-21 23:24:41 PST
Sample interval1 hour
Measurements85
Calvert Beach Lookout weather station
Data from this location is also available here, on Weather Underground.
Webcam images from this location are available here.
Disclaimer: With the goal of supporting users, sensor data is published in near real-time and has not yet been quality controlled. Before using this data for analysis, please contact data@hakai.org to request any information that might be relevant to your objectives.

NOTE: Rain measurements from this sensor node are not reliable


NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph

Measurement summary

Measurement nameMeasurement unitLogger functionMeasurements foundMeasurements missingSensor information/measurement calculation
WindSpdLookout_Avg (WindSpd_Avg)m/sAvg2015105106C-10: Marine Wind Monitor SN=118427
WindSpdLookout_Min (WindSpd_Min)m/sMin2015105106C-10: Marine Wind Monitor SN=118427
WindSpdLookout_Max (WindSpd_Max)m/sMax2015105106C-10: Marine Wind Monitor SN=118427
WindSpdLookout_Std (WindSpd_Std)m/sStd2015105106C-10: Marine Wind Monitor SN=118427
WindDirLookout_Avg (WindDir_Avg)degreesAvg2015105106C-10: Marine Wind Monitor SN=118427
WindDirLookout_Std (WindDir_Std)degreesStd2015105106C-10: Marine Wind Monitor SN=118427
RH%Smp20142HC2S3: Temperature and Relative Humidity Probe SN=60837520
=rangeClip(minimumValue=0,maximumValue=100)
RH_Avg%Avg20142HC2S3: Temperature and Relative Humidity Probe SN=60837520
RH_Min%Min20142HC2S3: Temperature and Relative Humidity Probe SN=60837520
RH_Max%Max20142HC2S3: Temperature and Relative Humidity Probe SN=60837520
RH_Std%Std20142HC2S3: Temperature and Relative Humidity Probe SN=60837520
TAirLookout1 (AirTempLow)deg CSmp20151HC2S3: Temperature and Relative Humidity Probe SN=60837520
TAirLookout1_Avg (AirTempLow_Avg)deg CAvg20151HC2S3: Temperature and Relative Humidity Probe SN=60837520
TAirLookout1_Min (AirTempLow_Min)deg CMin20151HC2S3: Temperature and Relative Humidity Probe SN=60837520
TAirLookout1_Max (AirTempLow_Max)deg CMax20151HC2S3: Temperature and Relative Humidity Probe SN=60837520
TAirLookout1_Std (AirTempLow_Std)deg CStd20151HC2S3: Temperature and Relative Humidity Probe SN=60837520
TAirLookout2 (AirTempHigh)deg CSmp20151109: Temperature Probe
TAirLookout2_Avg (AirTempHigh_Avg)deg CAvg20151109: Temperature Probe
TAirLookout2_Min (AirTempHigh_Min)deg CMin20151109: Temperature Probe
TAirLookout2_Max (AirTempHigh_Max)deg CMax20151109: Temperature Probe
TAirLookout2_Std (AirTempHigh_Std)deg CStd20151109: Temperature Probe
EnclosureRH_Avg%Avg02016CS210: Specifications and Technical Data
EnclosureRH_Min%Min02016CS210: Specifications and Technical Data
EnclosureRH_Max%Max02016CS210: Specifications and Technical Data
PStnLookout (StationAirPressure)hPaSmp20151CS106: Barometric Pressure Sensor SN=H1060046
PStnLookout_Avg (StationAirPressure_Avg)hPaAvg20151CS106: Barometric Pressure Sensor SN=H1060046
PStnLookout_Min (StationAirPressure_Min)hPaMin20151CS106: Barometric Pressure Sensor SN=H1060046
PStnLookout_Max (StationAirPressure_Max)hPaMax20151CS106: Barometric Pressure Sensor SN=H1060046
PStnLookout_Std (StationAirPressure_Std)hPaStd20151CS106: Barometric Pressure Sensor SN=H1060046
PSeaLookout (SeaLevelAirPressure)hPaSmp20151CS106: Barometric Pressure Sensor SN=H1060046
PSeaLookout_Avg (SeaLevelAirPressure_Avg)hPaAvg20151CS106: Barometric Pressure Sensor SN=H1060046
PSeaLookout_Min (SeaLevelAirPressure_Min)hPaMin20151CS106: Barometric Pressure Sensor SN=H1060046
PSeaLookout_Max (SeaLevelAirPressure_Max)hPaMax20151CS106: Barometric Pressure Sensor SN=H1060046
PSeaLookout_Std (SeaLevelAirPressure_Std)hPaStd20151CS106: Barometric Pressure Sensor SN=H1060046
LWS_mV_AvgmVAvg20151
SolarRadW/m2Smp20151CMP3: Pyranometer SN=127171
SolarRad_AvgW/m2Avg20151CMP3: Pyranometer SN=127171
SolarRad_MinW/m2Min20151CMP3: Pyranometer SN=127171
SolarRad_MaxW/m2Max20151CMP3: Pyranometer SN=127171
SolarRad_StdW/m2Std20151CMP3: Pyranometer SN=127171
SolarRadHourlyTotalMJTot20151CMP3: Pyranometer SN=127171
Solar24HrLookout (24hourSolar)MJ24 hour total20160CMP3: Pyranometer SN=127171
=total(Lookout.1hourSamples.SolarRadHourlyTotal,24)
PARμmol/s.m2Smp20151PQS1: PAR Quantum sensor SN=120512
PAR_Avgμmol/s.m2Avg20151PQS1: PAR Quantum sensor SN=120512
PAR_Minμmol/s.m2Min20151PQS1: PAR Quantum sensor SN=120512
PAR_Maxμmol/s.m2Max20151PQS1: PAR Quantum sensor SN=120512
PAR_Stdμmol/s.m2Std20151PQS1: PAR Quantum sensor SN=120512
PARHourlyTotalmol/m2Tot20151PQS1: PAR Quantum sensor SN=120512
PAR24HrLookout (24hourPAR)mol/m224 hour total20160PQS1: PAR Quantum sensor SN=120512
=total(Lookout.1hourSamples.PARHourlyTotal,24)
EnclosureTemp_Avgdeg CAvg20151
EnclosureTemp_Mindeg CMin20151
EnclosureTemp_Maxdeg CMax20151
PanelTemp_Avgdeg CAvg20151CR1000: Data Logger
PanelTemp_Mindeg CMin20151CR1000: Data Logger
PanelTemp_Maxdeg CMax20151CR1000: Data Logger
BattVolt_AvgVoltsAvg20151CR1000: Data Logger
BattVolt_MinVoltsMin20151CR1000: Data Logger
BattVolt_MaxVoltsMax20151CR1000: Data Logger
KidBattVolt_AvgVoltsAvg20151MidNite KID: Charge controller
KidBattVolt_MinVoltsMin20151MidNite KID: Charge controller
KidBattVolt_MaxVoltsMax20151MidNite KID: Charge controller
KidPVVolt_AvgVoltsAvg20151MidNite KID: Charge controller
KidPVVolt_MinVoltsMin20151MidNite KID: Charge controller
KidPVVolt_MaxVoltsMax20151MidNite KID: Charge controller
KidOutputWatts_AvgWattsAvg20151MidNite KID: Charge controller
KidOutputWatts_MinWattsMin20151MidNite KID: Charge controller
KidOutputWatts_MaxWattsMax20151MidNite KID: Charge controller
KidKWH_AvgkWhAvg20151MidNite KID: Charge controller
KidKWH_MinkWhMin20151MidNite KID: Charge controller
KidKWH_MaxkWhMax20151MidNite KID: Charge controller
KidAmpHours_AvgAhAvg20151MidNite KID: Charge controller
KidAmpHours_MinAhMin20151MidNite KID: Charge controller
KidAmpHours_MaxAhMax20151MidNite KID: Charge controller
KidBattTemp_Avgdeg CAvg20151MidNite KID: Charge controller
KidBattTemp_Mindeg CMin20151MidNite KID: Charge controller
KidBattTemp_Maxdeg CMax20151MidNite KID: Charge controller
WBJRCurrent_AvgAmpsAvg20151MidNite KID: Charge controller
WBJRCurrent_MinAmpsMin20151MidNite KID: Charge controller
WBJRCurrent_MaxAmpsMax20151MidNite KID: Charge controller
KidBattSOC_Avg%Avg20151MidNite KID: Charge controller
KidBattSOC_Min%Min20151MidNite KID: Charge controller
KidBattSOC_Max%Max20151MidNite KID: Charge controller
WBJRAmpHrRemaining_AvgAhAvg20151MidNite KID: Charge controller
WBJRAmpHrRemaining_MinAhMin20151MidNite KID: Charge controller
WBJRAmpHrRemaining_MaxAhMax20151MidNite KID: Charge controller