Hakai > Data > Sensor Network > TSN2.1hourSamples (2026-01-30 00:00:00 PST - 2026-04-24 05:00:00 PST) Hakai, a Tula Foundation program
ParameterValue
Start time2026-01-30 00:00:00 PST
End time2026-04-24 05:00:00 PST
Generated time2026-04-24 05:40:42 PST
Sample interval1 hour
Measurements75
Terrestrial sensor node #2
Disclaimer: 0

NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph
NEW! click here to view and customize the following graph

Measurement summary

Station nameMeasurement nameMeasurement unitLogger functionMeasurements foundMeasurements missingSensor information/measurement calculation
TSN2TAirTSN2_Med (AirTemp_Med)deg CMed20220HC2S3: Temperature and Relative Humidity Probe SN=61081140
=median(TSN2.5minuteSamples.AirTemp_Avg)
TSN2TAirTSN2_Avg (AirTemp_Avg)deg CAvg20220HC2S3: Temperature and Relative Humidity Probe SN=61081140
=avg(TSN2.5minuteSamples.AirTemp_Avg)
TSN2TAirTSN2_Min (AirTemp_Min)deg CMin20220HC2S3: Temperature and Relative Humidity Probe SN=61081140
=min(TSN2.5minuteSamples.AirTemp_Avg)
TSN2TAirTSN2_Max (AirTemp_Max)deg CMax20220HC2S3: Temperature and Relative Humidity Probe SN=61081140
=max(TSN2.5minuteSamples.AirTemp_Avg)
TSN2RHTSN2_Med (RH_Med)%Med20220HC2S3: Temperature and Relative Humidity Probe SN=61081140
=median(TSN2.5minuteSamples.RH_Avg)
TSN2RHTSN2_Avg (RH_Avg)%Avg20220HC2S3: Temperature and Relative Humidity Probe SN=61081140
=avg(TSN2.5minuteSamples.RH_Avg)
TSN2RHTSN2_Min (RH_Min)%Min20220HC2S3: Temperature and Relative Humidity Probe SN=61081140
=min(TSN2.5minuteSamples.RH_Avg)
TSN2RHTSN2_Max (RH_Max)%Max20220HC2S3: Temperature and Relative Humidity Probe SN=61081140
=max(TSN2.5minuteSamples.RH_Avg)
TSN2TWtr_WTW16_Med (Well_PT_4_Temp_Med)deg CMed20220KPSI 353: Pressure Transducer SN=1505967
=median(fillGaps(TSN2.5minuteSamples.Well_PT_4_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW16_Avg (Well_PT_4_Temp_Avg)deg CAvg20220KPSI 353: Pressure Transducer SN=1505967
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_4_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW16_Min (Well_PT_4_Temp_Min)deg CMin20220KPSI 353: Pressure Transducer SN=1505967
=min(fillGaps(TSN2.5minuteSamples.Well_PT_4_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW16_Max (Well_PT_4_Temp_Max)deg CMax20220KPSI 353: Pressure Transducer SN=1505967
=max(fillGaps(TSN2.5minuteSamples.Well_PT_4_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW17_Med (Well_PT_5_Temp_Med)deg CMed20220KPSI 353: Pressure Transducer SN=1505964
=median(fillGaps(TSN2.5minuteSamples.Well_PT_5_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW17_Avg (Well_PT_5_Temp_Avg)deg CAvg20220KPSI 353: Pressure Transducer SN=1505964
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_5_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW17_Min (Well_PT_5_Temp_Min)deg CMin20220KPSI 353: Pressure Transducer SN=1505964
=min(fillGaps(TSN2.5minuteSamples.Well_PT_5_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW17_Max (Well_PT_5_Temp_Max)deg CMax20220KPSI 353: Pressure Transducer SN=1505964
=max(fillGaps(TSN2.5minuteSamples.Well_PT_5_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW18_Med (Well_PT_6_Temp_Med)deg CMed20220KPSI 353: Pressure Transducer SN=1505963
=median(fillGaps(TSN2.5minuteSamples.Well_PT_6_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW18_Avg (Well_PT_6_Temp_Avg)deg CAvg20220KPSI 353: Pressure Transducer SN=1505963
=avg(fillGaps(TSN2.5minuteSamples.Well_PT_6_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW18_Min (Well_PT_6_Temp_Min)deg CMin20220KPSI 353: Pressure Transducer SN=1505963
=min(fillGaps(TSN2.5minuteSamples.Well_PT_6_Temp_Avg,maxGapsFilled=240))
TSN2TWtr_WTW18_Max (Well_PT_6_Temp_Max)deg CMax20220KPSI 353: Pressure Transducer SN=1505963
=max(fillGaps(TSN2.5minuteSamples.Well_PT_6_Temp_Avg,maxGapsFilled=240))
TSN2WTD_WTW16 (WTW16_wtd)cmcalculated20220KPSI 353: Pressure Transducer SN=1505967
=fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240)
TSN2WTD_WTW16_Med (WTW16_wtd_Med)cmMed20220KPSI 353: Pressure Transducer SN=1505967
=median(fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240))
TSN2WTD_WTW16_Avg (WTW16_wtd_Avg)cmAvg20220KPSI 353: Pressure Transducer SN=1505967
=avg(fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240))
TSN2WTD_WTW16_Min (WTW16_wtd_Min)cmMin20220KPSI 353: Pressure Transducer SN=1505967
=min(fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240))
TSN2WTD_WTW16_Max (WTW16_wtd_Max)cmMax20220KPSI 353: Pressure Transducer SN=1505967
=max(fillGaps(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=140,riserHeight=40),maxGapsFilled=240))
TSN2WTD_WTW17 (WTW17_wtd)cmcalculated20220KPSI 353: Pressure Transducer SN=1505964
=waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40)
TSN2WTD_WTW17_Med (WTW17_wtd_Med)cmMed20220KPSI 353: Pressure Transducer SN=1505964
=median(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40))
TSN2WTD_WTW17_Avg (WTW17_wtd_Avg)cmAvg20220KPSI 353: Pressure Transducer SN=1505964
=avg(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40))
TSN2WTD_WTW17_Min (WTW17_wtd_Min)cmMin20220KPSI 353: Pressure Transducer SN=1505964
=min(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40))
TSN2WTD_WTW17_Max (WTW17_wtd_Max)cmMax20220KPSI 353: Pressure Transducer SN=1505964
=max(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=135,riserHeight=40))
TSN2WTD_WTW18 (WTW18_wtd)cmcalculated20220KPSI 353: Pressure Transducer SN=1505963
=waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40)
TSN2WTD_WTW18_Med (WTW18_wtd_Med)cmMed20220KPSI 353: Pressure Transducer SN=1505963
=median(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40))
TSN2WTD_WTW18_Avg (WTW18_wtd_Avg)cmAvg20220KPSI 353: Pressure Transducer SN=1505963
=avg(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40))
TSN2WTD_WTW18_Min (WTW18_wtd_Min)cmMin20220KPSI 353: Pressure Transducer SN=1505963
=min(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40))
TSN2WTD_WTW18_Max (WTW18_wtd_Max)cmMax20220KPSI 353: Pressure Transducer SN=1505963
=max(waterTableDepth(scale(fillGaps(clipWL(minimumValue=0.01,clipRangeBefore=2,clipRangeAfter=2,maxClipRange=240),maxGapsFilled=240),multiplier=100),deploymentDepth=125,riserHeight=40))
TSN2TSoilTSN2S4_40_Med (Soil_Temp_1_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1551
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_40_Avg (Soil_Temp_1_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1551
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_40_Min (Soil_Temp_1_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1551
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_40_Max (Soil_Temp_1_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1551
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_10_Med (Soil_Temp_2_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1553
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_10_Avg (Soil_Temp_2_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1553
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_10_Min (Soil_Temp_2_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1553
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_10_Max (Soil_Temp_2_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1553
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_25_Med (Soil_Temp_3_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1555
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_25_Avg (Soil_Temp_3_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1555
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_25_Min (Soil_Temp_3_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1555
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S4_25_Max (Soil_Temp_3_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1555
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_25_Med (Soil_Temp_4_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1558
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_25_Avg (Soil_Temp_4_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1558
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_25_Min (Soil_Temp_4_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1558
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_25_Max (Soil_Temp_4_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1558
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_10_Med (Soil_Temp_5_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1560
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_10_Avg (Soil_Temp_5_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1560
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_10_Min (Soil_Temp_5_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1560
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_10_Max (Soil_Temp_5_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1560
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_40_Med (Soil_Temp_6_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1554
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_40_Avg (Soil_Temp_6_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1554
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_40_Min (Soil_Temp_6_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1554
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S8_40_Max (Soil_Temp_6_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1554
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_10_Med (Soil_Temp_7_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1561
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_10_Avg (Soil_Temp_7_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1561
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_10_Min (Soil_Temp_7_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1561
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_10_Max (Soil_Temp_7_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1561
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_25_Med (Soil_Temp_8_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1556
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_25_Avg (Soil_Temp_8_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1556
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_25_Min (Soil_Temp_8_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1556
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_25_Max (Soil_Temp_8_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1556
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_40_Med (Soil_Temp_9_Med)deg CMed20220109AM: Soil Temperature Probe SN=c1548
=median(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_40_Avg (Soil_Temp_9_Avg)deg CAvg20220109AM: Soil Temperature Probe SN=c1548
=avg(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_40_Min (Soil_Temp_9_Min)deg CMin20220109AM: Soil Temperature Probe SN=c1548
=min(rangeClip(minimumValue=-20,maximumValue=30))
TSN2TSoilTSN2S6_40_Max (Soil_Temp_9_Max)deg CMax20220109AM: Soil Temperature Probe SN=c1548
=max(rangeClip(minimumValue=-20,maximumValue=30))
TSN2BattVolt_AvgVoltsAvg20220CR1000: Data Logger
TSN2BattVolt_MinVoltsMin20220CR1000: Data Logger
TSN2BattVolt_MaxVoltsMax20220CR1000: Data Logger
TSN3Rain24HrTSN3 (24hourRain)mm24 hour total20220TB4: Tipping-bucket Rain Gauge SN=14-1711
=total(total(TSN3.5minuteSamples.Rain,12),24)